Pressure valves
Relief, reducing, compensator controls without transducer. With or without on-board digital drivers. ATEX, IECEx, EAC, CCC, PESO, cULus certifications for gas II 2G, dust II 2D and mining I M2.
General Information
RZMA-AES,
AGMZA-AES
Pressure valves
Relief, direct or piloted, on-board driver, without transducer, fieldbus. ATEX, IECEx, EAC, CCC - II 2G, II 2D
06 ÷ 32
4 ÷ 600
l/min
250
bar
RZMA-A, HZMA-A, AGMZA-A
Pressure valves
![RZMA-A, HZMA-A, AGMZA-A RZMA-A, HZMA-A, AGMZA-A](/medias/AGMZA-A-32-S24.jpg-300Wx300H?context=bWFzdGVyfHJvb3R8NjQ3M3xpbWFnZS9qcGVnfGhmMi9oMzQvODgxODg5OTcxNDA3OC5qcGd8MWY3YjVhYmJjNzJlNWVjODBlYzYxM2JjZWExZjQ4ODBhNDI4NmU2ZWFhZjhiNTAzMmNmODA2YmVkMGMyZDZlZA)
Relief, direct or piloted, off-board driver, without transducer. ATEX, IECEx, EAC, CCC, PESO, cULus - II 2G, II 2D, I M2
06 ÷ 32
4 ÷ 600
l/min
250
bar
RZGA-AES,
AGRCZA-AES
Pressure valves
Reducing, direct or piloted, on-board driver, without transducer, fieldbus. ATEX, IECEx, EAC, CCC - II 2G, II 2D
06 ÷ 20
12 ÷ 300
l/min
250
bar
RZGA-A, HZGA-A, KZGA-A, AGRCZA-A
Pressure valves
![RZGA-A, HZGA-A, KZGA-A, AGRCZA-A RZGA-A, HZGA-A, KZGA-A, AGRCZA-A](/medias/RZGA-A-033-S32.jpg-300Wx300H?context=bWFzdGVyfHJvb3R8ODQzM3xpbWFnZS9qcGVnfGgyMC9oNzUvODgxODkyNTkyODQ3OC5qcGd8NDViYjkwMmZiNjY4MTE5NjRjMGY4ZGUzNjVkNmM4MTM5MmE2OGE4OTNhMDU1MmI2N2NiNzEyZGNkNzk1OTk5Mw)
Reducing, direct or piloted, off board driver, without transducer. ATEX, IECEx, EAC, CCC, PESO, cULus - II 2G, II 2D, I M2
06 ÷ 20
12 ÷ 300
l/min
250
bar
LIMZA-AES, LIRZA-AES, LICZA-AES
Pressure valves
Relief, reducing & compensator ISO cartridges, on-board driver, without transducer, fieldbus. ATEX, IECEx, EAC, CCC - II 2G, II 2D
16 ÷ 80
160 ÷ 4500
l/min
250
bar
LIMZA-A, LIRZA-A, LICZA-A
Pressure valves
![LIMZA-A, LIRZA-A, LICZA-A LIMZA-A, LIRZA-A, LICZA-A](/medias/LIMZA-1-S50.jpg-300Wx300H?context=bWFzdGVyfHJvb3R8NjExNHxpbWFnZS9qcGVnfGhlMi9oYzcvODgxODkyMzgzMTMyNi5qcGd8NjVlMjJhODQ3Y2MwZTE0M2E3ZWM5ODg2YjI1ZjEzMTBkZDRjNTAzZjliNDg1YjJiMjhhMTljMjQ5MjdhMjU0ZA)
Relief, reducing & compensator ISO cartridges, off board driver, without transducer. ATEX, IECEx, EAC, CCC, PESO, cULus - II 2G, II 2D, I M2
16 ÷ 80
160 ÷ 4500
l/min
250
bar
DHRZA-AES
Pressure valves
3 way reducing for pilot lines, direct, on-board driver, without transducer, fieldbus. ATEX, IECEx, EAC, CCC - II 2G, II 2D
06
24
l/min
25
bar
DHRZA-A
Pressure valves
3 way reducing for pilot lines, direct, off-board driver, without transducer. ATEX, IECEx, EAC, CCC, PESO, cULus - II 2G, II 2D, I M2
06
24
l/min
25
bar