Atos is certified according to the main international standards with the application of IATF automotive methods
Certifications
HEALTH SAFETY ENVIRONMENT
ATEX
ATEX 2014/34/EU Production Quality Assurance Notification - QAN
Notification of the production quality system according to Annex IV of the Directive 2014/34/EU.
ATEX 2014/34/EU EN ISO 80079-36, EN ISO 80079-37
Ex-proof vane pumps type PFEA and AXIAL piston pumps type PVPCA for surface plants with gas, vaporous, mists and dust Zone 1, 2, 21 and 22
Ex II 2/2G Ex h IIC T5, T4 Gb
Ex II 2/2D Ex h IIIC T100°C, T135°C Db
Ex II 2/2G Ex h IIC T5, T4 Gb
Ex II 2/2D Ex h IIIC T100°C, T135°C Db
ATEX 2014/34/EU EN ISO 80079-36, EN ISO 80079-37
Ex-proof locations cylinders type CKA and servocylinders type CKAM for surface plants with gas, vaporous, mists and dust - Zone 1, 2, 21 and 22
Ex II 2G Ex h IIC T6, T4 Gb
Ex II 2D Ex h IIIC T85°C, T135°C Db
Ex II 2G Ex h IIC T6, T4 Gb
Ex II 2D Ex h IIIC T85°C, T135°C Db
ATEX 2014/34/EU EN IEC 60079-0, EN 60079-1, EN 60079-31
Ex-proof on-off, proportional and stainless steel solenoids for surface plants with gas, vaporous and dust - Zone 1, 2, 21 and 22
Ex II 2G Ex db IIC T6,T4,T3 Gb
Ex II 2D Ex tb IIIC T85°C, T135°C, T200°C Db IP66/67
Ex II 2G Ex db IIC T6,T4,T3 Gb
Ex II 2D Ex tb IIIC T85°C, T135°C, T200°C Db IP66/67
ATEX 2014/34/EU EN IEC 60079-0, EN 60079-1, EN 60079-31
Ex-proof position transducers LVDT for surface plants with gas, vaporous and dust - Zone 1, 2, 21 and 22
Ex II 2G Ex db IIC T6, T5, T4 Gb IP66/67
Ex II 2D Ex tb IIIC T85°C, T100°C, T135°C Db IP66/67
Ex II 2G Ex db IIC T6, T5, T4 Gb IP66/67
Ex II 2D Ex tb IIIC T85°C, T100°C, T135°C Db IP66/67
ATEX 2014/34/EU EN IEC 60079-0 and EN 60079-1
Ex-proof on-off and proportional solenoids for mines and surface installations with grisou and or flammable dust
Ex I M2 Ex db I Mb IP66/67
Ex I M2 Ex db I Mb IP66/67
ATEX 2014/34/EU EN IEC 60079-0 and EN 60079-1, EN 60079-31
Ex-proof proportional solenoids with on-board digital electronics for surface plants with gas, vaporous and dust - Zone 1, 2, 21 and 22
Ex II 2G Ex db IIC T6…T4 Gb
Ex II 2D Ex tb IIIC T85°C...T135°C Db IP66/67
Ex II 2G Ex db IIC T6…T4 Gb
Ex II 2D Ex tb IIIC T85°C...T135°C Db IP66/67
IECEx
IECEx Certification scheme for Explosive atmospheres IEC 600079-0, IEC60079-1, IEC 600079-31
Ex-proof on-off, proportional and stainless steel solenoids for surface plants with gas, vaporous and dust - Zone 1, 2, 21 and 22
Ex db IIC T6 or T4 or T3 Gb
Ex tb IIIC T85°C or T135°C or T200°C Db IP 66/67
Ex db IIC T6 or T4 or T3 Gb
Ex tb IIIC T85°C or T135°C or T200°C Db IP 66/67
IECEx Certification scheme for Explosive atmospheres IEC 60079-0, IEC 60079-1
Ex-proof on-off and proportional solenoids for mines and surface installations with grisou and or flammable dust
Ex db I Mb IP66/67
Ex db I Mb IP66/67
IECEx Certification scheme for Explosive atmospheres IEC 60079-0, IEC 60079-1, IEC 60079-31
Ex-proof position transducers LVDT for surface plants with gas, vaporous and dust - Zone 1, 2, 21 and 22
Ex db IIC T6 or T5 or T4 Gb
Ex tb IIIC T85°C or T100°C or T135°C Db IP 66/67
Ex db IIC T6 or T5 or T4 Gb
Ex tb IIIC T85°C or T100°C or T135°C Db IP 66/67
IECEx Certification scheme for Explosive atmospheres IEC 60079-0, IEC 60079-1, IEC 60079-31
Ex-proof proportional solenoids with on-board digital electronics for surface plants with gas, vaporous and dust - Zone 1, 2, 21 e 22
Ex db IIC T6...T4 Gb
Ex tb IIIC T85°C...T135°C Db IP66/67b
Ex db IIC T6...T4 Gb
Ex tb IIIC T85°C...T135°C Db IP66/67b
IECEx certification scheme for explosive atmospheres IEC 60079-0, IEC 60079-11
On-off intrinsically safe solenoids for surface plants with gas or vaporous - Zone 0, 1 and 2 or mines with grisou and or flammable dust
Ex ia IIC T6 Ga, Ex ia IIC T5 Ga, Ex ia I Ma (only /M version)
Tenv.: -40°C ÷ +60°C or -40°C ÷ +45°C
Ex ia IIC T6 Ga, Ex ia IIC T5 Ga, Ex ia I Ma (only /M version)
Tenv.: -40°C ÷ +60°C or -40°C ÷ +45°C
CCC
CCC Ex China Compulsory Certification GB/T 3836.1-2021, GB/T 3836.2-2021, GB/T 3836.31-2021
Ex-proof on-off and proportional solenoids, ex-proof stainless steel solenoids for surface plants with gas, vaporous and dust - Zone 1, 2, 21 and 22.
Ex db IIC T6, T4, T3 Gb
Ex tb IIIC T85°C, T135°C, T200°C Db
Ex db IIC T6, T4, T3 Gb
Ex tb IIIC T85°C, T135°C, T200°C Db
CCC Ex China Compulsory Certification GB/T 3836.1-2021, GB/T 3836.2-2021, GB/T 3836.31-2021
Ex-proof position transducers LVDT for surface plants with gas, vaporous and dust - Zone 1, 2, 21 and 22
Ex db IIC T6, T5, T4 Gb
Ex tb IIIC T85°C, T100°C, T135°C Db
Ex db IIC T6, T5, T4 Gb
Ex tb IIIC T85°C, T100°C, T135°C Db
SAFETY
SAFETY VALVES 2006/42/CE, EN ISO 13849-1, EN ISO 13849-2
Safety components according to the machine directive
Direct, piloted operated valves and cartridges with mechanical micro switch or inductive proximity sensor or inductive position sensors
Direct, piloted operated valves and cartridges with mechanical micro switch or inductive proximity sensor or inductive position sensors
HYDRAULICS BLOCKS 2006/42/CE, EN ISO 13849-1, EN ISO 13849-2
Directive for downstroking Press Brakes - metal forming
Standard PBAC and PBBC solutions for CNC synchronized press brakes - TÜV certified
Standard PBAC and PBBC solutions for CNC synchronized press brakes - TÜV certified