Atos proportional pressure control valves and ISO cartridges integrate a pressure transducer to offer superior performances for hysteresis, response time, linearity and stability.
The on board digital driver control in closed loop the valve’s regulation and also corrects non-linearity and regulation drifts, thanks to the integral pressure transducer feedback.
The valve is provided with four preset configurations of dynamic response to match different hydraulic conditions, software selectable by Atos PC software or in real time via fieldbus communication.
Open-loop configuration can be selected for system troubleshooting or maintenance purpose.
Fieldbus interface are optionally available: CANopen, PROFIBUS DP, EtherCAT
Max pressure 350 bar - Max flow up to 4.500 l/min.